Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38082890

RESUMEN

Sleep position affects sleep quality and the severity of different diseases. Classical methods to measure sleep position are complex, expensive, and difficult to use outside the laboratory. Wearables and smartphones can help to address these issues to track sleep position at home over several nights. In this study, we monitor high-resolution sleep position in 13 adolescents over 4 nights using smartphone accelerometer data. We aim to investigate the distribution of sleep positions and position changes in adolescents, study their variability across nights, and propose new measures related to nocturnal body movements. We developed a new index, the mean sleep angle change per hour, and calculated three other measures: position shifts per hour, mean time at each position, and periods of immobility. Our results indicate that participants spent 56% of the time on the side (32% right and 24% left), 32% in supine, and 12% in prone position, similar to what happens in adults. However, adolescents moved more than adults during sleep according to all measures. There was some variability between nights, but lower than the inter-subject variability. In conclusion, this work systematically analyzes sleep position over several nights in adolescents, a largely unstudied population, and offers innovative solutions and measures for high-resolution sleep position monitoring in a simple and cost-effective way.Clinical Relevance- Our study characterizes sleep position in adolescents and provides novel unobtrusive methods and quantitative indices to monitor high-resolution sleep position at home during multiple nights.


Asunto(s)
Sueño , Teléfono Inteligente , Adulto , Humanos , Adolescente , Movimiento , Posicionamiento del Paciente , Acelerometría
2.
ERJ Open Res ; 9(3)2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37131524

RESUMEN

Background: Acute respiratory syndrome due to coronavirus 2 (SARS-CoV-2) is characterised by heterogeneous levels of disease severity. It is not necessarily apparent whether a patient will develop severe disease or not. This cross-sectional study explores whether acoustic properties of the cough sound of patients with coronavirus disease 2019 (COVID-19), the illness caused by SARS-CoV-2, correlate with their disease and pneumonia severity, with the aim of identifying patients with severe disease. Methods: Voluntary cough sounds were recorded using a smartphone in 70 COVID-19 patients within the first 24 h of their hospital arrival, between April 2020 and May 2021. Based on gas exchange abnormalities, patients were classified as mild, moderate or severe. Time- and frequency-based variables were obtained from each cough effort and analysed using a linear mixed-effects modelling approach. Results: Records from 62 patients (37% female) were eligible for inclusion in the analysis, with mild, moderate and severe groups consisting of 31, 14 and 17 patients respectively. Five of the parameters examined were found to be significantly different in the cough of patients at different disease levels of severity, with a further two parameters found to be affected differently by the disease severity in men and women. Conclusions: We suggest that all these differences reflect the progressive pathophysiological alterations occurring in the respiratory system of COVID-19 patients, and potentially would provide an easy and cost-effective way to initially stratify patients, identifying those with more severe disease, and thereby most effectively allocate healthcare resources.

3.
Sensors (Basel) ; 23(7)2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-37050431

RESUMEN

In this study, we propose a model-based tool for the detection of obstructive apnea episodes by using ECG features from a single lead channel. Several sequences of recurrent apnea were provoked in separate 15-min periods in anesthetized rats during an experimental model of obstructive sleep apnea (OSA). Morphology-based ECG markers and the beat-to-beat interval (RR) were assessed in each sequence. These markers were used to train dynamic Bayesian networks (DBN) with different orders and feature combinations to find a good tradeoff between network complexity and apnea-detection performance. By using a filtering approach, the resulting DBNs were used to infer the apnea probability signal for subsequent episodes in the same rat. These signals were then processed using by 15-s epochs to determine whether epochs were classified as apneic or nonapneic. Our results showed that fifth-order models provided suitable RMSE values, since higher order models become significantly more complex and present worse generalization. A global threshold of 0.2 gave the best overall performance for all combinations tested, with Acc = 81.3%, Se = 69.8% and Sp = 81.5%, using only two parameters including the RR and Ds (R-wave downslope) markers. We concluded that multivariate models using DBNs represent a powerful tool for detecting obstructive apnea episodes in short segments, which may also serve to estimate the number of total events in a given time period.


Asunto(s)
Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Ratas , Animales , Teorema de Bayes , Electrocardiografía/métodos , Apnea Obstructiva del Sueño/diagnóstico , Modelos Teóricos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3257-3260, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36085642

RESUMEN

Wearable bioimpedance is a technique proposed to estimate breathing parameters such as respiratory rate (RR). However, its potential application lies in clinical investigation of daily-life activities like walking. This study evaluated the effect of the walking interference on the estimation of breathing parameters. 50 chronic obstructive pulmonary disease patients performed static and active measurements during thoracic bioimpedance acquisition. The static measurements included respiratory airflow for reference. The active measurements were used to estimate the walking interference from bioimpedance, and the obtained signals were added to static measurements for comparison with the reference. Afterward, we applied four different preprocessing methods to remove this walking interference and the resulting signals were used to detect the respiratory cycles and estimate breathing parameters (inspiratory time, expiratory time, duty cycle, and RR). The methods performed differently in terms of accuracy and mean average percentage error (MAPE), showing the need for specific preprocessing for active measurements. Furthermore, the MAPE values in the RR estimation were close to 3 % indicating that breathing parameters can be accurately estimated during walking. Accordingly, the present study reinforces the applicability of wearable bioimpedance for respiratory monitoring. Clinical relevance- This study exhibits the suitability of wearable bioimpedance to estimate accurate breathing param-eters during walking activities.


Asunto(s)
Algoritmos , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico/métodos , Respiración , Caminata
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 666-669, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36085651

RESUMEN

Although sleep apnea is one of the most prevalent sleep disorders, most patients remain undiagnosed and untreated. The gold standard for sleep apnea diagnosis, polysomnography, has important limitations such as its high cost and complexity. This leads to a growing need for novel cost-effective systems. Mobile health tools and deep learning algorithms are nowadays being proposed as innovative solutions for automatic apnea detection. In this work, a convolutional neural network (CNN) is trained for the identification of apnea events from the spectrograms of audio signals recorded with a smartphone. A systematic comparison of the effect of different window sizes on the model performance is provided. According to the results, the best models are obtained with 60 s windows (sensitivity-0.72, specilicity-0.89, AUROC = 0.88), For smaller windows, the model performance can be negatively impacted, because the windows become shorter than most apnea events, by which sound reductions can no longer be appreciated. On the other hand, longer windows tend to include multiple or mixed events, that will confound the model. This careful trade-off demonstrates the importance of selecting a proper window size to obtain models with adequate predictive power. This paper shows that CNNs applied to smartphone audio signals can facilitate sleep apnea detection in a realistic setting and is a first step towards an automated method to assist sleep technicians. Clinical Relevance- The results show the effect of the window size on the predictive power of CNNs for apnea detection. Furthermore, the potential of smartphones, audio signals, and deep neural networks for automatic sleep apnea screening is demonstrated.


Asunto(s)
Síndromes de la Apnea del Sueño , Teléfono Inteligente , Algoritmos , Humanos , Redes Neurales de la Computación , Polisomnografía , Síndromes de la Apnea del Sueño/diagnóstico
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3273-3276, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36085676

RESUMEN

In this study, we proposed an automatic detector for obstructive apnea episodes using only ECG-based time-series from a single-ECG channel. Several obstructive apnea episodes were provoked for different separated sequences of 15 minutes in anesthetized Sprague-Dawley rats. In this recurrent obstructive sleep apnea (OSA) model, each episode lasted 15s, while the number of total events per sequence was randomly selected. The beat-to-beat interval ( RR) and the R-wave amplitude ( Ra) time-series were extracted and processed for each sequence, and used to train Dynamic Bayesian Networks with different lags. An optimal trade-off between the lag ( L) and RMSE values was considered to select the best model to be used when detecting apnea episodes. The selected models were then used to estimate the occurrence probability of apnea episodes, p(At), by using a filtering approach. Finally, the time-series of the estimated probabilities were post-processed using non-overlapped 15-s epochs, to determine whether they are classified as apneic or non-apneic segments. Results showed that those lagged models with orders greater than 5, presented suitable RMSE values and become more sensitive as the order increased. A detection threshold of 0.2 seems to provide the best apnea detection performance overall, with Acc=0.81, Se=0.83 and Sp=0.79, using two ECG parameters and L=10. Clinical relevance- Dynamic Bayesian Networks represent a powerful tool to develop personalized models for apnea detection and diagnosis in OSA patients.


Asunto(s)
Obstrucción de las Vías Aéreas , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Animales , Teorema de Bayes , Electrocardiografía , Ratas , Ratas Sprague-Dawley , Apnea Obstructiva del Sueño/diagnóstico
7.
IEEE J Biomed Health Inform ; 26(12): 5983-5991, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36121947

RESUMEN

Breathing pattern has been shown to be different in chronic obstructive pulmonary disease (COPD) patients compared to healthy controls during rest and walking. In this study we evaluated respiratory parameters and the breathing variability of COPD patients as a function of their severity. Thoracic bioimpedance was acquired on 66 COPD patients during the performance of the six-minute walk test (6MWT), as well as 5 minutes before and after the test while the patients were seated, i.e. resting and recovery phases. The patients were classified by their level of airflow limitation into moderate and severe groups. We characterized the breathing patterns by evaluating common respiratory parameters using only wearable bioimpedance. Specifically, we computed the median and the coefficient of variation of the parameters during the three phases of the protocol, and evaluated the statistical differences between the two COPD severity groups. We observed significant differences between the COPD severity groups only during the sitting phases, whereas the behavior during the 6MWT was similar. Particularly, we observed an inverse relationship between breathing pattern variability and COPD severity, which may indicate that the most severely diseased patients had a more restricted breathing compared to the moderate patients.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Dispositivos Electrónicos Vestibles , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Pulmón , Respiración , Prueba de Paso
8.
Comput Methods Programs Biomed ; 225: 107020, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35905697

RESUMEN

BACKGROUND AND OBJECTIVE: Chronic obstructive pulmonary disease (COPD) requires a multifactorial assessment, evaluating the airflow limitation and symptoms of the patients. The 6-min walk test (6MWT) is commonly used to evaluate the functional exercise capacity in these patients. This study aims to propose a novel predictive model of the major 6MWT outcomes for COPD assessment, without physical performance measurements. METHODS: Cardiopulmonary and clinical parameters were obtained from fifty COPD patients. These parameters were used as inputs of a Bayesian network (BN), which integrated three multivariate models including the 6-min walking distance (6MWD), the maximum HR (HRmax) after the walking, and the HR decay 3 min after (HRR3). The use of BN allows the assessment of the patients' status by predicting the 6MWT outcomes, but also inferring disease severity parameters based on actual patient's 6MWT outcomes. RESULTS: Firstly, the correlation obtained between the estimated and actual 6MWT measures was strong (R = 0.84, MAPE = 8.10% for HRmax) and moderate (R = 0.58, MAPE = 15.43% for 6MWD and R = 0.58, MAPE = 32.49% for HRR3), improving the classical methods to estimate 6MWD. Secondly, the classification of disease severity showed an accuracy of 78.3% using three severity groups, which increased up to 84.4% for two defined severity groups. CONCLUSIONS: We propose a powerful two-way assessment tool for COPD patients, capable of predicting 6MWT outcomes without the need for an actual walking exercise. This model-based tool opens the way to implement a continuous monitoring system for COPD patients at home and to provide more personalized care.


Asunto(s)
Tolerancia al Ejercicio , Enfermedad Pulmonar Obstructiva Crónica , Teorema de Bayes , Prueba de Esfuerzo/métodos , Humanos , Rendimiento Físico Funcional , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Caminata
9.
IEEE J Biomed Health Inform ; 26(7): 3385-3396, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35404825

RESUMEN

This study explored the use of parasternal second intercostal space and lower intercostal space surface electromyogram (sEMG) and surface mechanomyogram (sMMG) recordings (sEMGpara and sMMGpara, and sEMGlic and sMMGlic, respectively) to assess neural respiratory drive (NRD), neuromechanical (NMC) and neuroventilatory (NVC) coupling, and mechanical efficiency (MEff) noninvasively in healthy subjects and chronic obstructive pulmonary disease (COPD) patients. sEMGpara, sMMGpara, sEMGlic, sMMGlic, mouth pressure (Pmo), and volume (Vi) were measured at rest, and during an inspiratory loading protocol, in 16 COPD patients (8 moderate and 8 severe) and 9 healthy subjects. Myographic signals were analyzed using fixed sample entropy and normalized to their largest values (fSEsEMGpara%max, fSEsMMGpara%max, fSEsEMGlic%max, and fSEsMMGlic%max). fSEsMMGpara%max, fSEsEMGpara%max, and fSEsEMGlic%max were significantly higher in COPD than in healthy participants at rest. Parasternal intercostal muscle NMC was significantly higher in healthy than in COPD participants at rest, but not during threshold loading. Pmo-derived NMC and MEff ratios were lower in severe patients than in mild patients or healthy subjects during threshold loading, but differences were not consistently significant. During resting breathing and threshold loading, Vi-derived NVC and MEff ratios were significantly lower in severe patients than in mild patients or healthy subjects. sMMG is a potential noninvasive alternative to sEMG for assessing NRD in COPD. The ratios of Pmo and Vi to sMMG and sEMG measurements provide wholly noninvasive NMC, NVC, and MEff indices that are sensitive to impaired respiratory mechanics in COPD and are therefore of potential value to assess disease severity in clinical practice.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Electromiografía/métodos , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Respiración , Mecánica Respiratoria , Índice de Severidad de la Enfermedad
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5508-5511, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892372

RESUMEN

Many studies have focused on novel noninvasive techniques to monitor respiratory rate such as bioimpedance. We propose an algorithm to detect respiratory phases using wearable bioimpedance to compute time parameters like respiratory rate, inspiratory and expiratory times, and duty cycle. The proposed algorithm was compared with two other algorithms from literature designed to estimate the respiratory rate using physiological signals like bioimpedance. We acquired bioimpedance and airflow from 50 chronic obstructive pulmonary disease (COPD) patients during an inspiratory loading protocol. We compared performance of the algorithms by computing accuracy and mean average percentage error (MAPE) between the bioimpedance parameters and the reference parameters from airflow. We found similar performance for the three algorithms in terms of accuracy (>0.96) and respiratory time and rate errors (<3.42 %). However, the proposed algorithm showed lower MAPE in duty cycle (10.18 %), inspiratory time (10.65 %) and expiratory time (8.61 %). Furthermore, only the proposed algorithm kept the statistical differences in duty cycle between COPD severity levels that were observed using airflow. Accordingly, we suggest bioimpedance to monitor breathing pattern parameters in home situations.Clinical relevance- This study exhibits the suitability of wearable thoracic bioimpedance to detect respiratory phases and to compute accurate breathing pattern parameters.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Dispositivos Electrónicos Vestibles , Algoritmos , Humanos , Pulmón , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Frecuencia Respiratoria
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5535-5538, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892378

RESUMEN

Patients suffering from obstructive sleep apnea (OSA) usually present an increased sympathetic activity caused by the intermittent hypoxia effect on autonomic control. This study evaluated the relationship between sleep stages and the apnea duration, frequency, and type, as well as their impact on HRV markers in different groups of disease severity. The hypnogram and R-R interval signals were extracted in 81 OSA patients from night polysomnographic (PSG) recordings. The apnea-hypopnea index (AHI) defined patient classification as mild-moderate (AHI<=30, n=44) or severe (AHI>30, n=37). The normalized power in VLH, LF, and HF bands of RR series were estimated by a time-frequency approach and averaged in 1-min epochs of normal and apnea segments. The autonomic response and the impact of sleep stages were assessed in both segments to compare patient groups. Deeper sleep stages (particularly S2) concentrated the shorter and mild apnea episodes (from 10 to 40 s) compared to light (SWS) and REM sleep. Longer episodes (>50 s) although less frequent, were of similar incidence in all stages. This pattern was more pronounced for the group of severe patients. Moreover, during apnea segments, LFnu was higher (p=0.044) for the severe group, since V LFnu and HFnu presented the greatest changes when compared to normal segments. The non-REM sleep seems to better differentiate OSA patients groups, particularly through VLFnu and HFnu(p<0.001). A significant difference in both sympathetic and vagal modulation between REM and non-REM sleep was only found within the severe group. These results confirm the importance of considering sleep stages for HRV analysis to further assess OSA disease severity, beyond the traditional and clinically limited AHI values.Clinical relevance-Accounting for sleep stages during HRV analysis could better assess disease severity in OSA patients.


Asunto(s)
Apnea Obstructiva del Sueño , Fases del Sueño , Frecuencia Cardíaca , Humanos , Polisomnografía , Sueño REM
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5574-5577, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892387

RESUMEN

Obstructive sleep apnea (OSA) is a sleep disorder in which repetitive upper airway obstructive events occur during sleep. These events can induce hypoxia, which is a risk factor for multiple cardiovascular and cerebrovascular diseases. Chronic obstructive pulmonary disease (COPD) is a disorder which induces a persistent inflammation of the lungs. This condition produces hypoventilation, affecting the blood oxygenation, and leads to an increased risk of developing lung cancer and heart disease. In this study, we evaluated how COPD affects the severity and characteristics of OSA in a multivariate demographic database including polysomnographic signals. Results showed SpO2 subtle variations, such as more non-recovered desaturations and increased time below a 90% SpO2 level, which, in the long term, could worsen the risk to suffer cardiovascular and cerebrovascular diseases.Clinical Relevance- COPD increases the OSA risk due to hypoventilation and altered SpO2 behavior.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Apnea Obstructiva del Sueño , Estudios Epidemiológicos , Humanos , Saturación de Oxígeno , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/epidemiología , Síndrome
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5582-5585, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892389

RESUMEN

Fixed sample entropy (fSampEn) is a promising technique for the analysis of respiratory electromyographic (EMG) signals. Its use has shown outperformance of amplitude-based estimators such as the root mean square (RMS) in the evaluation of respiratory EMG signals with cardiac noise and a high correlation with respiratory signals, allowing changes in respiratory muscle activity to be tracked. However, the relationship between the fSampEn response to a given muscle activation has not been investigated. The aim of this study was to analyze the nature of the fSampEn measurements that are produced as the EMG activity increases linearly. Simulated EMG signals were generated and increased linearly. The effect of the parameters r and the size of the moving window N of the fSampEn were evaluated and compared with those obtained using the RMS. The RMS showed a linear trend throughout the study. A non-linear, sigmoidal-like behavior was found when analyzing the EMG signals using the fSampEn. The lower the values of r, the higher the non-linearity observed in the fSampEn results. Greater moving windows reduced the variation produced by too small values of r.Clinical Relevance- Understanding the inherent non-linear relationship produced when using the fSampEn in EMG recordings will contribute to the improvement of the respiratory muscle activation assessment at different levels of respiratory effort in patients with respiratory conditions, particularly during the inspiratory phase.


Asunto(s)
Músculos Respiratorios , Frecuencia Respiratoria , Electromiografía , Entropía , Corazón , Humanos
14.
Sensors (Basel) ; 21(21)2021 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-34770489

RESUMEN

Patients with spinal cord injury (SCI) have an increased risk of sleep-disordered breathing (SDB), which can lead to serious comorbidities and impact patients' recovery and quality of life. However, sleep tests are rarely performed on SCI patients, given their multiple health needs and the cost and complexity of diagnostic equipment. The objective of this study was to use a novel smartphone system as a simple non-invasive tool to monitor SDB in SCI patients. We recorded pulse oximetry, acoustic, and accelerometer data using a smartphone during overnight tests in 19 SCI patients and 19 able-bodied controls. Then, we analyzed these signals with automatic algorithms to detect desaturation, apnea, and hypopnea events and monitor sleep position. The apnea-hypopnea index (AHI) was significantly higher in SCI patients than controls (25 ± 15 vs. 9 ± 7, p < 0.001). We found that 63% of SCI patients had moderate-to-severe SDB (AHI ≥ 15) in contrast to 21% of control subjects. Most SCI patients slept predominantly in supine position, but an increased occurrence of events in supine position was only observed for eight patients. This study highlights the problem of SDB in SCI and provides simple cost-effective sleep monitoring tools to facilitate the detection, understanding, and management of SDB in SCI patients.


Asunto(s)
Síndromes de la Apnea del Sueño , Traumatismos de la Médula Espinal , Humanos , Polisomnografía , Calidad de Vida , Síndromes de la Apnea del Sueño/diagnóstico , Teléfono Inteligente , Traumatismos de la Médula Espinal/diagnóstico
15.
J Neural Eng ; 18(4)2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-34340222

RESUMEN

Objective.Impaired trunk stability is frequent in spinal cord injury (SCI), but there is a lack of quantitative measures for assessing trunk function. Our objectives were to: (a) evaluate trunk muscle activity and movement patterns during a reaching task in SCI patients, (b) compare the impact of cervical (cSCI) and thoracic (tSCI) injuries in trunk function, and (c) investigate the effects of a startling acoustic stimulus (SAS) in these patients.Approach.Electromyographic (EMG) and smartphone accelerometer data were recorded from 15 cSCI patients, nine tSCI patients, and 24 healthy controls, during a reaching task requiring trunk tilting. We calculated the response time (RespT) until pressing a target button, EMG onset latencies and amplitudes, and trunk tilt, lateral deviation, and other movement features from accelerometry. Statistical analysis was applied to analyze the effects of group (cSCI, tSCI, control) and condition (SAS, non-SAS) in each outcome measure.Main results.SCI patients, especially those with cSCI, presented significantly longer RespT and EMG onset latencies than controls. Moreover, in SCI patients, forward trunk tilt was accompanied by significant lateral deviation. RespT and EMG latencies were remarkably shortened by the SAS (the so-called StartReact effect) in tSCI patients and controls, but not in cSCI patients, who also showed higher variability.Significance. The combination of EMG and smartphone accelerometer data can provide quantitative measures for the assessment of trunk function in SCI. Our results show deficits in postural control and compensatory strategies employed by SCI patients, including delayed responses and higher lateral deviations, possibly to improve sitting balance. This is the first study investigating the StartReact responses in trunk muscles in SCI patients and shows that the SAS significantly accelerates RespT in tSCI, but not in cSCI, suggesting an increased cortical control exerted by these patients.


Asunto(s)
Traumatismos de la Médula Espinal , Electromiografía , Humanos , Movimiento , Músculo Esquelético , Equilibrio Postural , Traumatismos de la Médula Espinal/diagnóstico
16.
Sensors (Basel) ; 21(13)2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34282793

RESUMEN

Poor sleep quality or disturbed sleep is associated with multiple health conditions. Sleep position affects the severity and occurrence of these complications, and positional therapy is one of the less invasive treatments to deal with them. Sleep positions can be self-reported, which is unreliable, or determined by using specific devices, such as polysomnography, polygraphy or cameras, that can be expensive and difficult to employ at home. The aim of this study is to determine how smartphones could be used to monitor and treat sleep position at home. We divided our research into three tasks: (1) develop an Android smartphone application ('SleepPos' app) which monitors angle-based high-resolution sleep position and allows to simultaneously apply positional treatment; (2) test the smartphone application at home coupled with a pulse oximeter; and (3) explore the potential of this tool to detect the positional occurrence of desaturation events. The results show how the 'SleepPos' app successfully determined the sleep position and revealed positional patterns of occurrence of desaturation events. The 'SleepPos' app also succeeded in applying positional therapy and preventing the subjects from sleeping in the supine sleep position. This study demonstrates how smartphones are capable of reliably monitoring high-resolution sleep position and provide useful clinical information about the positional occurrence of desaturation events.


Asunto(s)
Aplicaciones Móviles , Teléfono Inteligente , Estudios Transversales , Humanos , Multimorbilidad , Sueño , Posición Supina
17.
Sensors (Basel) ; 21(11)2021 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-34073215

RESUMEN

Poor sleep quality is a risk factor for multiple mental, cardiovascular, and cerebrovascular diseases. Certain sleep positions or excessive position changes can be related to some diseases and poor sleep quality. Nevertheless, sleep position is usually classified into four discrete values: supine, prone, left and right. An increase in sleep position resolution is necessary to better assess sleep position dynamics and to interpret more accurately intermediate sleep positions. This research aims to study the feasibility of smartphones as sleep position monitors by (1) developing algorithms to retrieve the sleep position angle from smartphone accelerometry; (2) monitoring the sleep position angle in patients with obstructive sleep apnea (OSA); (3) comparing the discretized sleep angle versus the four classic sleep positions obtained by the video-validated polysomnography (PSG); and (4) analyzing the presence of positional OSA (pOSA) related to its sleep angle of occurrence. Results from 19 OSA patients reveal that a higher resolution sleep position would help to better diagnose and treat patients with position-dependent diseases such as pOSA. They also show that smartphones are promising mHealth tools for enhanced position monitoring at hospitals and home, as they can provide sleep position with higher resolution than the gold-standard video-validated PSG.


Asunto(s)
Sueño , Teléfono Inteligente , Acelerometría , Humanos , Polisomnografía , Posición Supina
18.
Sensors (Basel) ; 21(5)2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33806463

RESUMEN

This study aims to investigate noninvasive indices of neuromechanical coupling (NMC) and mechanical efficiency (MEff) of parasternal intercostal muscles. Gold standard assessment of diaphragm NMC requires using invasive techniques, limiting the utility of this procedure. Noninvasive NMC indices of parasternal intercostal muscles can be calculated using surface mechanomyography (sMMGpara) and electromyography (sEMGpara). However, the use of sMMGpara as an inspiratory muscle mechanical output measure, and the relationships between sMMGpara, sEMGpara, and simultaneous invasive and noninvasive pressure measurements have not previously been evaluated. sEMGpara, sMMGpara, and both invasive and noninvasive measurements of pressures were recorded in twelve healthy subjects during an inspiratory loading protocol. The ratios of sMMGpara to sEMGpara, which provided muscle-specific noninvasive NMC indices of parasternal intercostal muscles, showed nonsignificant changes with increasing load, since the relationships between sMMGpara and sEMGpara were linear (R2 = 0.85 (0.75-0.9)). The ratios of mouth pressure (Pmo) to sEMGpara and sMMGpara were also proposed as noninvasive indices of parasternal intercostal muscle NMC and MEff, respectively. These indices, similar to the analogous indices calculated using invasive transdiaphragmatic and esophageal pressures, showed nonsignificant changes during threshold loading, since the relationships between Pmo and both sEMGpara (R2 = 0.84 (0.77-0.93)) and sMMGpara (R2 = 0.89 (0.85-0.91)) were linear. The proposed noninvasive NMC and MEff indices of parasternal intercostal muscles may be of potential clinical value, particularly for the regular assessment of patients with disordered respiratory mechanics using noninvasive wearable and wireless devices.


Asunto(s)
Diafragma , Músculos Intercostales , Electromiografía , Voluntarios Sanos , Humanos , Mecánica Respiratoria
19.
Sci Rep ; 11(1): 5363, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33686167

RESUMEN

Trunk stability is essential to maintain upright posture and support functional movements. In this study, we aimed to characterize the muscle activity and movement patterns of trunk flexion during an arm reaching task in sitting healthy subjects and investigate whether trunk stability is affected by a startling acoustic stimulus (SAS). For these purposes, we calculated the electromyographic (EMG) onset latencies and amplitude parameters in 8 trunk, neck, and shoulder muscles, and the tilt angle and movement features from smartphone accelerometer signals recorded during trunk bending in 33 healthy volunteers. Two-way repeated measures ANOVAs were applied to examine the effects of SAS and target distance (15 cm vs 30 cm). We found that SAS markedly reduced the response time and EMG onset latencies of all muscles, without changing neither movement duration nor muscle recruitment pattern. Longer durations, higher tilt angles, and higher EMG amplitudes were observed at 30 cm compared to 15 cm. The accelerometer signals had a higher frequency content in SAS trials, suggesting reduced movement control. The proposed measures have helped to establish the trunk flexion pattern in arm reaching in healthy subjects, which could be useful for future objective assessment of trunk stability in patients with neurological affections.


Asunto(s)
Acelerometría , Electromiografía , Voluntarios Sanos , Movimiento/fisiología , Postura/fisiología , Teléfono Inteligente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
20.
IEEE Trans Biomed Eng ; 68(1): 298-307, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32746014

RESUMEN

Chronic Obstructive Pulmonary Disease (COPD) is one of the most common chronic conditions. The current assessment of COPD requires a maximal maneuver during a spirometry test to quantify airflow limitations of patients. Other less invasive measurements such as thoracic bioimpedance and myographic signals have been studied as an alternative to classical methods as they provide information about respiration. Particularly, strong correlations have been shown between thoracic bioimpedance and respiratory volume. The main objective of this study is to investigate bioimpedance and its combination with myographic parameters in COPD patients to assess the applicability in respiratory disease monitoring. We measured bioimpedance, surface electromyography and surface mechanomyography in forty-three COPD patients during an incremental inspiratory threshold loading protocol. We introduced two novel features that can be used to assess COPD condition derived from the variation of bioimpedance and the electrical and mechanical activity during each respiratory cycle. These features demonstrate significant differences between mild and severe patients, indicating a lower inspiratory contribution of the inspiratory muscles to global respiratory ventilation in the severest COPD patients. In conclusion, the combination of bioimpedance and myographic signals provides useful indices to noninvasively assess the breathing of COPD patients.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Músculos Respiratorios , Humanos , Mediciones del Volumen Pulmonar , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Respiración , Espirometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...